Aceproof Ener-G' guard


Description

ACEPROOF Ener-G’guard - High performance acrylic elastomeric coating has excellent elongation and can maintain a watertight seal while the roof expands and contracts for certain extent. It has high resistance to organic growth and has UV resistance properties too. ACEPROOF Ener-G’guard - High performance acrylic elastomeric waterproofing coating saves money on cooling costs by reducing the heat transferred to the inside of your building.

  • For interior and exterior application for water resistance purpose.
  • Provides a seamless, elastic and durable membrane.
  • Contains fungicides and mildewcides.
  • Superior adhesion to various substrates.
  • Reflective roof coating helps reduce cooling costs, prevents UV-degradation and premature roof failure.
  • Easy to use, non-toxic and VOC-compliant water based roof coating.
  • Can be applied by brush, roller, spray or squeegee.

Uses:

  • RCC Structure
  • Sloping roofs
  • Cooling towers
  • Masonry walls
  • Restoration of building
Mixing

ACEPROOF Ener-G’guard - High performance acrylic elastomeric coating is ready-to-use liquid. Shake the container well before use. Thinning is not recommended.

Remove all standing water by vacuum or blowing with oil-free, compressed air prior to installation. ACEPROOF Ener-G’guard - High performance acrylic elastomeric coating should be installed on dry surfaces. Apply ACEPROOF Ener-G’guard - High performance acrylic elastomeric coating by brush, roller, spray or squeegee. Give 3-4 hour drying time before installation of second coat. Second coat should be applied on opposite direction.

Recommended substrates:
  • RCC Structure
  • Sloping roofs
  • Cooling towers
  • Masonry walls
  • Restoration of building
Surface preparation

Concrete surface must be sound, clean and free of all contaminants that could impair product adhesion, bond or performance. Concrete should be a minimum of 28 days old or substantially cured to the equivalent design strength prior to installation. Remove all loose or deteriorated concrete by chipping hammer, water jetting, or other mechanical means to achieve an open pore structure and sound concrete surface. Remove all cleaning media and debris by vacuum or blowing with high-pressure, oil-free air.

For OLD CONCRETE:

Thoroughly clean surface with a grease-cutting detergent to remove grease and oils, and remove any loose or unsound concrete by chipping, scarifying, shot blasting, sanding, or grinding. Proceed as for new poured concrete.

For PREVIOUSLY COATED CONCRETE:

: Remove any peeling or degraded paint by sanding or using a paint stripper. For intact paint, thoroughly clean the surface with a strong detergent, then lightly sand to remove any gloss. Treat any areas worn down to the original concrete as bare concrete.

Pack size:

Available in 5 litre and 20 litre in off-white colour.

Shelf life:

12 months, if stored in cool and dry area in unopened containers, protected from sun light. Shelf life is calculated from the month of manufacturing of the product.

Curing and Protection

Curing time is affected by ambient, surface temperatures and humidity. Water proofed area should be completely covered up to 24 hours.

Grouting

Grouting can be done after 24 hrs of installation of tiles. Use Acegrout superfine series grout for up to 3mm joints and Acegrout coarse series grout for 3 - 12 mm joints. Use Acepoxy Epoxy grout for stain and chemical resistance, hygienic grout. Please call customer service executive for more information.

Caution:
  • It is not recommended to use on surface where continuous temperature exposure above 100°C.
  • Not recommended in some manufacturing facilities where heavy chemicals are used. Consult Technical Services on questionable installations.
  • Colours may be slightly different than shown. When colour considerations are critical, a mock-up should be constructed prior to final application.
  • The use of safety glasses and chemically resistant gloves is recommended. Use appropriate clothing to minimize skin contact. The use of a NIOSH-approved respirator is required to protect respiratory tract when ventilation is not adequate to limit exposure below the PEL. Refer to Material Safety Data Sheet (MSDS) available for detailed information.